Risk assessment of neuromuscular stimulation by energy-based transurethral resection devices: an ex vivo test standard

基于能量的经尿道切除装置引起神经肌肉刺激的风险评估:一项体外测试标准

阅读:1

Abstract

BACKGROUND: During transurethral resection of bladder tumours (TURB), radio-frequency (RF) currents can lead to adverse neuromuscular stimulation (NMS). Here we present a novel ex vivo method to determine the risk of RF generators and their bipolar TURB modes to cause NMS. We aimed to develop an experimental platform for safety evaluation of new RF generators and their modes with a newly established test standard, suitable for replacement or reduction of animal testing. METHODS: We tested four contemporary RF generators with their bipolar modes for TURB in saline. A two-stage ex vivo approach was pursued: First, we recorded voltages at possible positions of the obturator nerve behind a porcine bladder wall in a TURB model using 18 RF applications per generator. Second, these voltage records were used as stimuli to evoke nerve compound action potentials (CAPs) in isolated porcine axillary nerves. The NMS potential was defined as the ratio between the observed area under the CAPs and the theoretical CAP area at maximum response and a firing rate of 250 Hz, which would reliably induce tetanic muscle responses in most human subjects. The measurement protocol was tailored to optimise reproducibility of the obtained NMS potentials and longevity of the nerve specimens. RESULTS: As prerequisite for the clinical translation of our results, the robustness of our test method and reproducibility of the NMS potential are demonstrated with an excellent correlation (r = 0.93) between two sets of identical stimuli (n = 72 each) obtained from 16 nerve segments with similar diameters (4.2 ± 0.37 mm) in the nerve model. The RF generators differed significantly (p < 0.0001) regarding NMS potential (medians: 0-3%). CONCLUSIONS: Our test method is suitable for quantifying the NMS potential of different electrosurgical systems ex vivo with high selectivity at a reasonable degree of standardization and with justifiable effort. Our results suggest that the clinical incidence of NMS is considerably influenced by the type of RF generator. Future generations of RF generators take advantage from the proposed test standard through higher safety and less animal testing. Health professionals and treated patients will benefit most from improved RF surgery using generators with a low NMS risk.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。