Test-retest reliability of a novel unilateral thoracic expansion measurement using stretchable strain sensors

利用可拉伸应变传感器进行新型单侧胸廓扩张测量的重测信度

阅读:1

Abstract

[Purpose] We report here a new method for measuring unilateral thoracic expansion using stretchable strain sensors. In this study, we assessed the test-retest reliability of this method and compared left and right thoracic expansions in healthy males. [Participants and Methods] Thirty healthy males (mean age, 30.1 ± 7.4 years) participated in this study. Two strain sensors were placed on the lateral walls of the thorax at xiphoid process level. Participants were asked to take three deep breaths, and the change in sensor length from the position at maximal expiration to that at maximal inspiration was recorded. These measurements were simultaneously performed on left and right sides. Unilateral thoracic expansions were calculated to assess differences between the maximal expiratory and inspiratory positions for each deep breath. The test-retest reliability of the unilateral thoracic expansion was then examined. [Results] Test reliability was excellent for both first and second datasets. Retest reliability was also excellent. The minimum detectable change (MDC) in the retest was 3.31 mm. [Conclusion] This newly developed method for measuring thoracic expansion is sufficiently reliable. No differences in thoracic expansion were observed between left and right sides in healthy males.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。