Adequacy of lymph node transbronchial needle aspirates using convex probe endobronchial ultrasound for multiple tumor genotyping techniques in non-small-cell lung cancer

凸阵探头支气管内超声引导下经支气管针吸活检术对非小细胞肺癌多种肿瘤基因分型技术的适用性

阅读:1

Abstract

INTRODUCTION: Adequate tumor acquisition is essential to identify somatic molecular alterations in non-small-cell lung cancer (NSCLC), such as epidermal growth factor receptor (EGFR) mutations and anaplastic lymphoma kinase (ALK) translocations. The success and failure rates for tumor genotyping of tissue obtained from fine-needle aspirates of nodal tissue using a convex probe endobronchial ultrasound (CP-EBUS) and other diagnostic modalities in routine NSCLC care have not been described. METHODS: Clinicopathologic data, tumor genotype success and failure rates were retrospectively compiled and analyzed from 207 patient-tumor samples sent for routine tumor genotype in clinical practice, including 42 patient-tumor samples obtained from hilar or mediastinal lymph nodes using CP-EBUS. RESULTS: The median age of the patients was 65 years, 62.3% were women, 77.8% were white, 26.6% were never smokers, 73.9% had advanced NSCLC, and 84.1% had adenocarcinoma histology. Tumor tissue was obtained from CP-EBUS-derived hilar or mediastinal nodes in 42 cases (20.2% of total). In this latter cohort, the overall success rate for EGFR mutation analysis was 95.2%, for Kirsten rat sarcoma viral oncogene homolog (KRAS) mutation 90.5%, and for ALK fluorescence in situ hybridization 90.5%. In the complete 207 tumors, the success rate for EGFR was 92.3%, for KRAS 91.8%, and for ALK 89.9%. The failure rates were not significantly different when comparing CP-EBUS-derived nodal tissue versus all other samples or versus surgical biopsies of mediastinal nodes, but were significantly lower than image-guided percutaneous transthoracic core-needle biopsies. CONCLUSIONS: The success rate of multiple tumor genomic analyses techniques for EGFR, KRAS, and ALK gene abnormalities using routine lung cancer tissue samples obtained from hilar or mediastinal lymph nodes by means of CP-EBUS exceeds 90%, and this method of tissue acquisition is not inferior to other specimen types. Tumor genotype techniques are feasible in most CP-EBUS-derived samples and therefore further expansion of routine tumor genotype for the care of patients with NSCLC may be possible using targeted sample acquisition through CP-EBUS.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。