Reliability of an adapted core strength endurance test battery in individuals with axial spondylarthritis

针对中轴型脊柱关节炎患者的改良核心力量耐力测试方案的可靠性

阅读:1

Abstract

OBJECTIVES: To adapt the core strength endurance test battery (aCSE), previously used for testing athletes, to a target group of patients with axial spondylarthritis (axSpA), to evaluate its intra-tester reliability and its associations with disease-specific factors. METHODS: A cross-sectional study was conducted at axSpA exercise therapy groups, including both axSpA patients and the physiotherapist group leaders (PTs). The aCSE was used to measure the isometric strength endurance of the ventral, lateral, and dorsal core muscle chains (measured in seconds), as well as to assess the disease-specific factors of functional status, self-reported pain, and perceived strength performance. The aCSE was repeated after 7-14 days to measure intra-tester reliability for the same rater (PT group leader). Reliability was calculated as an intra-class correlation coefficient (ICC) using a nested design. The associations between ventral, lateral, and dorsal strength endurance and the disease-specific factors were calculated using Pearson correlation coefficients. RESULTS: Study participants were 13 PT group leaders and 62 axSpA patients. The latter were all capable of performing the aCSE, with the exception of one individual. A moderate to substantial intra-rater reliability (ICCs (95%CI)) was found for the ventral (0.54 (0.35, 0.74)), lateral (0.52 (0.33, 0.70)), and dorsal (0.71 (0.58, 0.86)) core muscle chains. None of the aCSE measures correlated with the disease-specific factors. CONCLUSION: The aCSE was found to be a reliable test battery for assessing core strength endurance in axSpA patients. Interestingly, aCSE performance was not associated with any disease-specific factors. Key Points • The adapted core strength endurance test battery measures the isometric strength of the ventral, lateral and dorsal core muscle chains. • The adapted core strength endurance test battery showed a moderate to substantial intra-rater reliability for all three muscle chains tested in axSpA patients. • No correlations were found between the adapted core strength endurance test battery and the disease-specific factors of self-reported pain, functional status and perceived strength performance.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。