Diagnostic role of contrast-enhanced ultrasonography versus conventional B-mode ultrasonography in cirrhotic patients with early hepatocellular carcinoma: a retrospective study

对比增强超声与常规B型超声在早期肝细胞癌肝硬化患者诊断中的作用:一项回顾性研究

阅读:1

Abstract

BACKGROUND: Early diagnosis of hepatocellular carcinoma (HCC) is very important for the prognosis of patients. However, there are very few studies that compared the diagnostic accuracy of contrast-enhanced ultrasonography (CEUS) and B-mode ultrasonography for early HCC in cirrhotic patients. METHODS: This retrospective study included cirrhotic patients, who were suspected of early HCC between January 2020 and June 2021. The diagnosis of patients was based on the pathology results of surgery or biopsy. Demographic and clinical characteristics of included patients were recorded. The diagnoses of suspected lesions using both types of ultrasonography were recorded, and the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of early HCC in cirrhotic patients were calculated. RESULTS: Eventually, 137 patients with solitary lesions in the liver were included in this study, including 89 patients diagnosed with HCC and 48 patients diagnosed with non-HCC. The median diameter of suspected lesions was 26 mm, and the median level of alpha fetoprotein (AFP) was 37.2 ng/mL. When comparing the demographic and clinical characteristics of cirrhotic patients with HCC and non-HCC, it was found that patients with HCC had significantly higher levels of AFP than those with non-HCC (P=0.03). The sensitivity, specificity, PPV, NPV, and accuracy of CEUS in early HCC were 73%, 93.8%, 95.6%, 65.2% and 80.3%, respectively. In CEUS, all of these parameters were much higher than those in B-mode ultrasonography, i.e., 64%, 75%, 82.6%, 52.9%, and 67.9%. It was also found that the diagnostic accuracy of CEUS was much higher than that of B-mode ultrasonography especially regarding lesions <20 mm. To further improve the sensitivity of CEUS in early HCC, AFP was combined with CEUS for the diagnosis of early HCC. As a result, the sensitivity, specificity, PPV, NPV, and accuracy of CEUS combined with AFP level were 83.1%, 87.5%, 92.5%, 73.7%, and 84.7%, respectively. CONCLUSIONS: Our study confirmed that CEUS' diagnostic accuracy for early HCC in cirrhotic patients was significantly higher than that of B-mode ultrasonography. However, the sensitivity of CEUS needs to be improved further, and the combination of CEUS and AFP level may be a potential solution.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。