Comparative Utility of Transient and 2D Shear Wave Elastography for the Assessment of Liver Fibrosis in Clinical Practice

瞬态和二维剪切波弹性成像在临床实践中评估肝纤维化的比较应用价值

阅读:1

Abstract

The aim of the study was to investigate the feasibility and correlation of liver stiffness measurements (LSM) between 2D-shear wave elastography (2D-SWE) and transient elastography (TE) in patients with chronic liver disease. Over 4 months, 421 patients with chronic liver disease of any cause underwent LSM by 2D-SWE and TE (M and/or XL probe) and controlled attenuation parameter at the same visit. LSM was not feasible by TE in 16 (3.8%) and by 2D-SWE in 17 (4.0%) patients. Median LSM were 8.9 and 8.7 kPa with TE and 2D-SWE, respectively, having a strong correlation (r = 0.774, p < 0.001) in the total cohort and in any cause of liver disease (r = 0.747-0.806, p < 0.001). There was a strong agreement on diagnosis of severe fibrosis (k-statistic: 0.841, p < 0.001) or cirrhosis (k-statistic: 0.823, p < 0.001). Both methods had increased failure rates in patients with obesity and/or increased waist circumference. Among 104 obese patients, TE was more feasible than 2D-SWE (92.3% vs 85.6%, p < 0.001]. LSM by 2D-SWE are strongly correlated to LSM by TE independently of the etiology of chronic liver disease, stage of fibrosis, degree of liver steatosis, and patients' characteristics. TE with the XL probe may be superior in a minority of obese patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。