Evaluating the potential and problems of three-dimensional computed tomography measurements of arterial stenosis

评估三维计算机断层扫描测量动脉狭窄的潜力和问题

阅读:1

Abstract

Volume visualization is gaining widespread acceptance in medical applications. As its use increases, the issue of accuracy becomes critical. There have been very few studies examining the accuracy of volume rendering techniques. We studied the accuracy of hardware-assisted volume rendering for measurement of arterial stenosis in computed tomography (CT) data. The results of our study reveal that accurate measurements can be made from volume rendered CT data. However, error is present (absolute average error from 5.1% to 13.6%) and there is some variability, even for experts (standard deviation ranged from 4.8% to 15%). The evidence suggests that the choice of volume rendering (transfer function) parameters greatly affects the accuracy of the results. Accurate transfer function parameter selection is a difficult problem. Parameters that produce realistic images often provide inaccurate measurements. As the use of volume visualization grows and more inexperienced users begin using these tools for medical diagnosis and staging, new guidelines, aids, and techniques must be developed to ensure reliable, accurate visualization results.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。