Development and evaluation of different methods to assess download and display time of image web systems

开发和评估用于评估图像网络系统下载和显示时间的不同方法

阅读:1

Abstract

OBJECTIVES: The aim of this study was to develop and verify different methods of measuring time-to-display (TTD) for radiological images with image web systems (IWS). The process should be automatable in order to repeatedly perform a large number of measurements without human interaction. MATERIALS AND METHODS: Three methods were defined and compared with respect to usability, stability, and quality of results. Method 1 was based on Windows 2000 Performance Monitor, whereas method 2 employed phototransistors taped to the screen and connected to a separate PC. A software tool developed for method 3, which used Windows application programming interface (API) function, calls to read the color code assigned to specific pixels on the screen. RESULTS: Method 3 proved to be the most reliable and easy to automate. The accuracy is practically equivalent to method 2, but it proved to be far more automatable. Method 1 produced the largest mean error, was easily disturbed, but was also easy to set up and provided additional insights into the system's architecture especially if combined with method 3. CONCLUSIONS: To measure the performance of image distribution systems, any of these methods can be used, but method 3 proved to be superior.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。