Detection of atrial fibrillation in primary care with radial pulse palpation, electronic blood pressure measurement and handheld single-lead electrocardiography: a diagnostic accuracy study

在基层医疗中,利用桡动脉搏动触诊、电子血压测量和手持式单导联心电图检测房颤:一项诊断准确性研究

阅读:1

Abstract

OBJECTIVE: To determine the diagnostic accuracy of three tests-radial pulse palpation, an electronic blood pressure monitor and a handheld single-lead ECG device-for opportunistic screening for unknown atrial fibrillation (AF). DESIGN: We performed a diagnostic accuracy study in the intention-to-screen arm of a cluster randomised controlled trial aimed at opportunistic screening for AF in general practice. We performed radial pulse palpation, followed by electronic blood pressure measurement (WatchBP Home A) and handheld ECG (MyDiagnostick) in random order. If one or more index tests were positive, we performed a 12-lead ECG at shortest notice. Similarly, to limit verification bias, a random sample of patients with three negative index tests received this reference test. Additionally, we analysed the dataset using multiple imputation. We present pooled diagnostic parameters. SETTING: 47 general practices participated between September 2015 and August 2018. PARTICIPANTS: In the electronic medical record system of the participating general practices (n=47), we randomly marked 200 patients of ≥65 years without AF. When they visited the practice for any reason, we invited them to participate. Exclusion criteria were terminal illness, inability to give informed consent or visit the practice or having a pacemaker or an implantable cardioverter-defibrillator. OUTCOMES: Diagnostic accuracy of individual tests and test combinations to detect unknown AF. RESULTS: We included 4339 patients; 0.8% showed new AF. Sensitivity and specificity were 62.8% (range 43.1%-69.7%) and 91.8% (91.7%-91.8%) for radial pulse palpation, 70.0% (49.0%-80.6%) and 96.5% (96.3%-96.7%) for electronic blood pressure measurement and 90.1% (60.8%-100%) and 97.9% (97.8%-97.9%) for handheld ECG, respectively. Positive predictive values were 5.8% (5.3%-6.1%), 13.8% (12.2%-14.8%) and 25.2% (24.2%-25.8%), respectively. All negative predictive values were ≥99.7%. CONCLUSION: In detecting AF, electronic blood pressure measurement (WatchBP Home A), but especially handheld ECG (MyDiagnostick) showed better diagnostic accuracy than radial pulse palpation. TRIAL REGISTRATION NUMBER: Netherlands Trial Register No. NL4776 (old NTR4914).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。