Abstract
INTRODUCTION: In today's world, high-cost procedures are being examined, and alternative procedures are being developed. In this context, one frequently examined procedure is total knee replacement. PURPOSE: This study aims to examine the three different closure techniques used in total knee replacement. METHODS: This study is a prospective randomized controlled study. Two hundred participants who underwent total knee replacement surgery, were included in the study. Participants were randomly divided into three groups. Arthrotomy was performed using a medial parapatellar approach with a midline incision. Standard femoral and tibial cuts were followed by the implantation of a Smith and Nephew genesis II implant for all participants. Complications, joint range of motion, pain scores, certain movement degrees, and functional scores were investigated. RESULTS: Pre-op and post-op range of motion, knee society score, oxford knee score, certain movement degree values have shown no significant difference. Visual analogue scale values were different significantly between the groups. There is a statistical difference between the range of motion, knee society score, oxford knee score, certain movement degree and visual analogue scale values in repeated measurements. The most common complication was a hematoma. This was observed most frequently in the continuous vicryl suture group. The closure time in the Barbed group was significantly lower than in the other groups. DISCUSSION: Treatment for total knee replacement is a heavy economic burden. Health systems and hospitals are under pressure. The results obtained in our study show that there is no superiority of one closure technique over the other.