Repeated Pelvic Radiographs in Infants, After Harness Treatment for Developmental Dysplasia of the Hip, Carry Very Low Radiation Risk

婴儿在接受髋关节发育不良矫正治疗后,重复进行骨盆X光检查的辐射风险极低。

阅读:1

Abstract

OBJECTIVE: There are no data on the effect of X-Ray irradiation to the vulnerable pelvic organs of babies during DDH follow-up. This study aims to calculate, for the first time, the radiation exposure to infants during follow-up for DDH harness treatment, and thus quantify the lifetime risk of malignancy. METHODS: Patients who had completed 5 years' follow-up following successful Pavlik harness treatment were identified from the hospital DDH database. The radiation dose was extracted from the Computerised Radiology Information System database for every radiograph of every patient. The effective dose (ED) was calculated using conversion coefficients for age, sex and body region irradiated. Cumulative ED was compared to Health Protection Agency standards to calculate lifetime risk of malignancy from the radiographs. RESULTS: All radiographs of 40 infants, successfully treated in Pavlik harness for DDH, were assessed. The mean number of AP pelvis radiographs was 7.00 (range: 6-9, mode: 7). The mean cumulative ED was 0.25 mSv (Range: 0.11-0.46, SD: 0.07). This is far lower than the annual 'safe' limit for healthcare workers of 20 mSv and is categorised as "Very Low Risk". CONCLUSION: Clinicians involved in the treatment DDH can be re-assured that the cumulative radiation exposure from pelvic radiographs following Pavlik harness treatment is "Very Low Risk". Whilst being mindful of any radiation exposure in children, this study provides a scientific answer that help addresses parental concerns.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。