Chronic inflammatory response in the rat lung to commonly used contrast agents for videofluoroscopy

大鼠肺对常用视频荧光透视造影剂的慢性炎症反应

阅读:3
作者:Rumi Ueha, Nogah Nativ-Zeltzer, Taku Sato, Takao Goto, Takaharu Nito, Koichi Tsunoda, Peter C Belafsky, Tatsuya Yamasoba

Conclusion

Aspirated Ba particles did not clear from the lung within a month and caused mild chronic pulmonary inflammation. ICA and NICA did not cause any inflammatory responses in the lungs, suggesting that ICA and NICA may be safer CAs for VFSS than Ba. Level of evidence: NA.

Methods

Eight-week-old male Sprague Dawley rats were divided into five groups (n = 6, each group). Three groups underwent tracheal instillation of one of three CAs: barium sulfate (Ba), ionic iodinated contrast agent (ICA), and nonionic iodinated contrast agent (NICA). A sham group was instilled with air and a control group was instilled with saline. All animals were euthanized 30 days after treatment and histological and gene analyses were performed.

Results

No animal died after CA or sham/control aspiration. Ba particles remained after 30 days and caused histopathologic changes and inflammatory cell infiltration. Iodinated ICA and NICA did not result in perceptible histologic change. Expression of Tnf, an inflammatory cytokine was increased in only Ba aspirated rats (P = .0076). Other inflammatory cytokines and fibrosis-related genes did not alter between groups.