Repeat Transcatheter Aortic Valve Replacement and Follow-Up of Embolized Transcatheter Heart Valve After 13 Years

经导管主动脉瓣置换术再治疗及经导管心脏瓣膜栓塞术后13年随访

阅读:1

Abstract

A 79-year-old woman was treated with a 23-mm balloon-expandable transcatheter heart valve (THV) that was initially complicated by an embolized THV requiring deployment in the descending aorta. She presented 13-years later with a degenerated bioprosthesis requiring redo THV. Pre-procedural computed tomography was important in highlighting underexpansion of the initial THV and open leaflets in the embolized valve. (Level of Difficulty: Advanced.).