Orbital Atherectomy Through Left Main Stent Struts Complicated by Catheter Entrapment and Stent Avulsion

经左主干支架梁行轨道斑块切除术,导管嵌顿和支架撕脱并发症

阅读:1

Abstract

We performed orbital atherectomy in the left circumflex artery through a stent that jailed the circumflex artery ostium. The orbital atherectomy catheter was entrapped within the stent and the stent was avulsed during catheter withdrawal. We should consider this potential complication when performing orbital atherectomy in a jailed side branch. (Level of Difficulty: Advanced.).