Epitope length, genospecies dependency, and serum panel effect in the IR6 enzyme-linked immunosorbent assay for detection of antibodies to Borrelia burgdorferi

表位长度、基因型依赖性和血清样本组对IR6酶联免疫吸附试验检测伯氏疏螺旋体抗体的影响

阅读:1

Abstract

In the absence of erythema migrans, the basis for diagnosis of Lyme disease is the demonstration of an antibody response against Borrelia burgdorferi in an appropriate clinical setting. The C6 enzyme-linked immunosorbent assay, based on the IR6 region of VlsE, has become widely used in both the United States and Europe. We mapped the antigenic epitopes of IR6 to a shorter sequence that is equivalent in sensitivity and specificity to the full-length IR6 25-residue peptide. In addition, we observed significant differences in sensitivity between serum panels (60 to 100%), indicating that the selection of the serum panels can shape the apparent overall sensitivity of the assay. Contrary to prior reports, the assay sensitivity is greater when the IR6 peptide is derived from the sequence of the same infecting Borrelia genospecies. Using our North American panels and the two panels obtained from European Lyme disease patients, we determined that the IR6 assay that is based on a single genospecies of Borrelia spp. is not optimal for use as a universal diagnostic assay for Lyme disease.

特别声明