Effects of transfusion load and suction pressure on renal function in intraoperative salvage autotransfusion

术中自体输血中输血负荷和吸引压力对肾功能的影响

阅读:1

Abstract

Although some investigations have been performed to determine the effects of transfusion load and suction pressure on renal function during intraoperative salvage autotransfusion, the precise threshold is still undetermined. A total of 625 patients undergoing surgery with the Continuous AutoTransfusion System (CATSplus) were enrolled and divided into groups according to the utilized suction pressure and transfusion volume. Plasma free hemoglobin (FHB) and creatinine clearance (CCr) were assayed to indicate the renal function. Both 0.03 MPa suction (≥4-unit load) and >5 units transfusion changed the levels of FHB and CCr significantly when measured 24 h post-operation compared to pre-operation. Under 0.02 MPa suction (≥4-unit load), the alteration of FHB and CCr returned to normal after 24 h. Under 3 units transfusion, the levels of FHB and CCr at 6 and 12 h post-operation changed significantly compared to pre-operation (P<0.05 or P<0.01, respectively), and this alteration could be restored to normal at 72 h post-operation. After an exhaustive investigation, less than 4 units transfusion and less than 0.03 MPa suction pressure are recommended for intraoperative salvage autotransfusion.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。