Occlusal Analysis of Algorithm-designed Restoration Using Different Virtual Articulator Parameters: A Preliminary Study

基于不同虚拟颌架参数的算法设计修复体的咬合分析:一项初步研究

阅读:1

Abstract

INTRODUCTION AND AIMS: To investigate how different virtual articulator parameter settings influence clinical outcomes of posterior CAD/CAM restorations designed with the CEREC system's biogeneric model, specifically regarding occlusal rehabilitation. METHODS: Twenty participants (11 females, 9 males; mean age 35.50 ± 5.23 years) each received four crowns designed under one of four protocols: (1) No Virtual Articulator Parameters (NVAP), (2) Mean Virtual Articulator Parameters (MVAP), (3) Partially Personalised Virtual Articulator Parameters (PPVAP), and (4) Fully Personalised Virtual Articulator Parameters (FPVAP). Subjective comfort was assessed via the Visual Analogue Scale and Likert scale. Intraoral scans were analysed using Geomagic Control X 2020 software to assess occlusal contact areas and points at single-tooth and full-arch levels. One-year restoration survival was not recorded. RESULTS: MVAP and FPVAP showed significantly lower Visual Analogue Scale scores than NVAP (P = .0084, P = .0002, respectively). Likert scale ratings did not differ among groups (P = .9921). All crown designs reduced occlusal contact areas compared to the pre-preparation state (P < .05), with FPVAP exhibiting the most favorable outcomes, though not significantly different from other designs. Full-arch analysis revealed no significant changes in contact areas (P = .2645) or contact points (P = .5015). Two NVAP restorations fractured within one year (P = .0348), indicating a trend favoring increased parameter personalization. CONCLUSIONS: Mean-value or fully personalised virtual articulator parameters in CAD/CAM crown design yield superior patient comfort and maintain more accurate occlusal relationships compared to non-personalised approaches. Mean-value settings present a practical option for general clinical use, although larger-scale studies with extended follow-up are recommended. CLINICAL RELEVANCE: By integrating mean-value or fully personalised virtual articulator parameters into CAD/CAM restoration workflows, clinicians can significantly enhance patient comfort and occlusal accuracy. These findings highlight the importance of tailoring design parameters in routine practice to improve restoration outcomes and potentially lower the likelihood of failure.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。