Marginal and internal analysis of preheated dental fissure-sealing materials using optical coherence tomography

利用光学相干断层扫描技术对预热后的牙科窝沟封闭材料进行边缘和内部分析

阅读:1

Abstract

OBJECTIVES: This study aimed to evaluate the influence of pre-photoactivation temperature on the marginal and internal integrity (occurrence of voids) of fissure-sealing materials on occlusal fissures using optical coherence tomography (OCT). METHODS: Occlusal fissures of 40 human third molars were sealed using a resin-based fissure sealant (Fluroshield) and a flowable composite (Permaflo) photoactivated at 68 °C (preheated) or at room temperature (25 °C) (n=10). After sealing, the teeth were subjected to thermocycling (500 cycles, 5-55 °C) and 14 days of pH cycling (demineralisation for 6 hours/day and remineralisation for 18 hours/day). The occlusal surfaces were scanned in a buccolingual direction, and 20 tomographic images parallel to the long axis of each tooth were obtained. Images presenting marginal gaps and internal voids were counted and statistically analysed using analysis of variance and Tukey's test (P<0.05). RESULTS: There were statistically significant differences between materials and temperatures (P<0.01). The flowable composite had a lower percentage of gaps and internal voids than the resin-based sealant. Preheated materials had a lower percentage of gaps and internal voids than the materials at room temperature. CONCLUSION: Therefore, preheated flowable composite provided the best marginal sealing of fissures, and internal homogeneity of the material.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。