Patient-reported and radiographic outcomes of a porous-coated acetabular cup in robotic assisted total hip arthroplasty at 2-year follow up

机器人辅助全髋关节置换术中多孔涂层髋臼杯2年随访的患者报告和放射学结果

阅读:1

Abstract

INTRODUCTION: Several implant manufacturers have developed ultra-porous metal substrate acetabular components recently. Despite this, data on clinical and radiographic outcomes remain limited. Our study evaluated postoperative patient-reported outcome measures (PROMs) and radiographic analyses in patients fitted with a novel acetabular porous-coated component. METHODS: A total of 152 consecutive patients underwent a total hip arthroplasty by a single orthopaedic surgeon. All patients underwent surgery utilizing the same CT-scan based robotic-assisted device with the same porous cementless acetabular shell. They received standardized postoperative physical therapy, rehabilitation, and pain protocols. Preoperatively, first postoperative visit, 6-months, 1-year, and 2-years, patients were evaluated based on Western Ontario and McMaster Universities Arthritis Index (WOMAC) pain, physical function, and total scores; 2) Patient-Reported Outcomes Measurement Information System (PROMIS)-10 physical and mental scores; 3) Hip Disability and Osteoarthritis Outcome Score (HOOS)-Jr scores; as well as 4) acetabular component positions and 5) evidence of acetabular component loosening. RESULTS: Significant improvements were observed by 6 months in WOMAC pain, physical function, and total scores (p < 0.05), maintained at 1 and 2 years. PROMIS-10 physical scores also improved significantly from preoperative to 6 months postoperative and remained so at 1 and 2 years postoperative (p < 0.05). No significant changes were found in PROMIS-10 mental scores. HOOS-Jr scores significantly improved from preoperative to 6 months postoperative and remained so through 2 years (p < 0.05). At 6 months, slight changes were noted in abduction angle and horizontal and vertical offset. Radiolucencies, initially found in 3 shells, reduced to 1 shell with 2 new radiolucencies by 6 months, and remained stable with no subsequent operative interventions. At 1 year and 2 years, no radiographic abnormalities were noted, including complete resolution of prior radiolucencies as well as stable components. CONCLUSION: This porous cementless acetabular shell, implanted with CT-scan-based robotic-assisted techniques, demonstrated excellent postoperative PROMs at 2 years. Stable radiolucencies suggest good component stability. The early stable clinical and radiographic results suggest promising long-term outcomes with this device. LEVEL OF EVIDENCE: III (retrospective cohort study).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。