What drives hyperammonemic encephalopathy in AED users: monotherapy risks or polypharmacy perils?

AED使用者发生高氨血症性脑病的原因是什么:单药治疗的风险还是多药治疗的风险?

阅读:1

Abstract

BACKGROUND AND OBJECTIVES: Hyperammonemic encephalopathy (HE) is a serious side effect linked to sodium valproate (VPA). Recent case studies indicate that newer antiepileptic drugs (AEDs) might also trigger HE, whether used alone or alongside VPA. This study investigated the risk factors of HE linked to 10 AEDs using data from the FDA Adverse Event Reporting System (FAERS), focusing on VPA co-administration effects. METHODS: FAERS reports from the first quarter of 2013 to the third quarter of 2024 were examined for ten frequently prescribed antiepileptic drugs (AEDs): VPA, perampanel (PER), phenytoin (PHT), carbamazepine (CBZ), topiramate (TPM), lamotrigine (LTG), levetiracetam (LEV), oxcarbazepine (OXA), clonazepam (CZP), and zonisamide (ZNS). Hepatic event (HE) signals were evaluated using reporting odds ratios (ROR). A multivariate logistic regression analysis was conducted to assess risk factors (age, gender, indication, drug combinations). Particular attention was given to the effects of VPA in combination with LEV, TPM, olanzapine (OLZ), or quetiapine (QTP) on the risk of HE. RESULTS: A total of 1,456 HE-related events were identified, with 93.06% of these events linked to AEDs. VPA had the highest association with HE (ROR = 122.14, 95% CI: 110.16-135.41), followed by PER, which was independent of VPA (ROR = 52.62). Eight additional AEDs also indicated positive associations, mainly influenced by VPA (such as TPM and LEV). Identified risk factors for HE included age (with a lower risk observed in minors, OR = 0.61, 95% CI [0.50-0.76]) and clinical indication (with a lower risk in psychiatric disorders, OR = 0.74, 95% CI [0.62-0.89]). The combination of VPA+TPM significantly raised the risk of HE (OR = 3.38, 95% CI [2.25-5.06]) without negatively impacting outcomes. Furthermore, combinations of antipsychotic medications with VPA also indicated an increased risk of HE (OLZ+VPA: OR = 1.65, 95% CI [1.18-2.30], QTP+VPA: OR = 1.95, 95% CI [1.39-2.75]). CONCLUSION: This research underscores the possible danger of HE related to AEDs, with a particular focus on the risks tied to VPA and PER when used alone, as well as VPA in conjunction with TPM, OLZ, or QTP. It emphasizes the need to monitor ammonia levels in patients on AEDs, particularly those on polypharmacy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。