A Pilot Study on Pain and the Upregulation of Myoglobin through Low-frequency and High-amplitude Electrical Stimulation-induced Muscle Contraction

一项关于疼痛和低频高振幅电刺激诱导肌肉收缩上调肌红蛋白的初步研究

阅读:1

Abstract

[Purpose] It is well known that, in both in vivo and in vitro tests, muscle fatigue is produced by severe exercise, electrical stimulation, and so on. However, it is not clear whether or not low-frequency and high-amplitude modulation specifically affects serum myoglobin or urine myoglobin. The purpose of the present study was to determine the effect of low-frequency and high-amplitude modulation on serum myoglobin and urine myoglobin. [Methods] The study used whole blood samples and urine produced over 24 hours from the thirteen healthy subjects. [Results] There was a significant increase in serum myoglobin following electrical stimulation at a frequency of 10 Hz compared with the control group. Furthermore, within 24 hours, urine myoglobin also showed a significant increase for the test volunteers subjected to electrical stimulation at the 10 Hz frequency compared with the control group. However, there were no significant differences in the concentrations of hematologic results in subjects treated with electrical stimulation. [Conclusion] These results suggest that increased myoglobin related to muscle fatigue from electrical stimulation, particularly with a current of 10 Hz combined with a high-amplitude, may be partially related to increased muscle damage.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。