Safety Profile of Musculoskeletal Contrast-Enhanced Ultrasound with Sulfur Hexafluoride Contrast Agent

使用六氟化硫造影剂进行肌肉骨骼对比增强超声检查的安全性概况

阅读:1

Abstract

PURPOSE: Muscle, bone and tendon regeneration depend on the microperfusion of the corresponding tissue which can be quantified with contrast-enhanced ultrasound (CEUS) using sulfur hexafluoride contrast agent (SonoVue(®)). This study investigated the incidence of adverse events (AEs) in musculoskeletal patients and gives an overview of musculoskeletal CEUS applications. PATIENTS AND METHODS: Based on 13 studies in a standardized monocentric setting, a total of 2268 CEUS examinations in 764 patients were performed and AEs due to the administration of sulfur hexafluoride contrast agent were classified as either mild, moderate or severe. RESULTS: No fatal events occurred. AEs were reported in three cases, of which only one was classified as severe and two as mild. The total rate of all AEs was 0.13% and 0.04% for severe AEs. CONCLUSION: The present analysis confirms the safety of musculoskeletal CEUS using sulfur hexafluoride contrast agent with a lower rate of AEs than that reported for other contrast agents even in elderly patients with concomitant diseases.