Mechanical analysis of prosthetic bars and dental implants in 3 and 4 implant-supported overdenture protocols using finite element analysis

利用有限元分析法对3颗和4颗种植体支持式覆盖义齿方案中的义齿杆和种植体进行力学分析

阅读:2

Abstract

In some clinical situations, the installation of four or more dental implants may be infeasible. Therefore, the installation of protocol-type prostheses with only three implants may be necessary. The mechanical failures can hinder the success of the rehabilitation treatment. OBJECTIVE: To evaluate and compare the mechanical stress of the metallic prosthetic bar when installed over protocol-type prostheses of three and four implants, and to evaluate the stress on the dental implants. METHODOLOGY: Two three-dimensional human jaw models were created. In one model, four dental implants (P4) were designed and in the other model three dental implants (P3) were designed. In both models, according to the arrangement of the dental implants, prosthetic bars were designed. In a finite element analysis software, compressive forces were applied to the ends of both prosthetic bars, simulating the force application during mastication. Tension and stress dissipation were analyzed on the prosthetic bar and dental implants. RESULTS: Both P4 and P3 protocol-type prostheses supported the force efficiently without breaking the bar or the implants. Force dissipation along the bar was more homogeneous in the P3 prosthetic bar than in P4. In addition, P3 implants received a higher concentration of stress in relation to P4 implants. CONCLUSIONS: Prosthetic bars and dental implants withstand the stress of load application in both four and three implant protocol-type prostheses. Three-implants protocol showed more satisfactory force dissipation than the four-implant protocol.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。