Optical Coherence Tomography Observation of Gonio Structures during Microhook Ab Interno Trabeculotomy

光学相干断层扫描观察微钩内路小梁切开术中的房角结构

阅读:1

Abstract

INTRODUCTION: Intraoperative observation of ocular structures using microscope-integrated optical coherence tomography (iOCT) has been adopted recently. I report my initial feasibility assessment of iOCT for the incised trabecular meshwork observation during microhook ab interno trabeculotomy. CASE SERIES: Both the nasal and temporal sides or either side of the trabecular meshwork/inner wall of Schlemm's canal was incised more than 3 clock hours. After then, under observation using a Swan-Jacob gonioprism lens with the real-time 5-line scan mode, OCT images of the area were successfully acquired in 10 (83%) of 12 sides in nine eyes. Based on the appearance of the acquired images of the 10 sides, the trabeculotomy cleft could be classified into three incisional patterns, that is, six (60%) anterior-opening patterns (posterior-based flap), three (30%) middle-opening patterns (posterior- and anterior-based flaps), and one (10%) posterior-opening pattern (anterior-based flap), according to the predominant locations of the trabecular meshwork flaps. CONCLUSION: Intraoperative observation of the gonio structures including the trabeculotomy cleft was feasible using the RESCAN 700 in combination with a gonioprism.