Characterization of SnO2-based (68)Ge/ (68)Ga generators and (68)Ga-DOTATATE preparations: radionuclide purity, radiochemical yield and long-term constancy

SnO2 基 (68)Ge/ (68)Ga 发生器和 (68)Ga-DOTATATE 制剂的表征:放射性核素纯度、放射化学产率和长期恒定性

阅读:5
作者:Ferdinand Sudbrock, Thomas Fischer, Beate Zimmermanns, Mehrab Guliyev, Markus Dietlein, Alexander Drzezga, Klaus Schomäcker

Background

With the increasing utilization of (68)Ge-(68)Ga radionuclide generators, (68)Ga labelled peptides like DOTATATE are receiving more attention in nuclear medicine. On the one hand, the long half-life of the parent nuclide (68)Ge is an enormous advantage for routine applications, but the question of the long-term stability of the (68)Ge breakthrough arises, which up to now has scarcely been investigated. Method: A sum of 123 eluates from four different (68)Ge-(68)Ga generators (iThemba Labs, Faure, South Africa) and 115 samples of the prepared radiopharmaceutical (68)Ga-DOTATATE were measured first with a dose calibrator and again after decay of the eluted (68)Ga via gamma-ray spectrometry. A complete decay curve was recorded for one sample eluate. A further three eluates were eluted in ten fractions of 0.5 ml in order to obtain detailed information concerning the distribution of the two nuclides within the eluates. The influences of factors such as the amount of DOTATATE, addition of Fe(3+) salts and replacement of HEPES buffer with sodium acetate on the radiochemical synthesis were also tested.

Conclusion

Effective doses received by the patient from (68)Ge in the injected radiopharmaceutical (68)Ga-DOTATATE are lower than 0.1 μSv and are therefore practically negligible, especially when compared with the contribution of the PET radiopharmaceutical itself. Gamma-ray spectrometry as recommended by the European Pharmacopeia is suitable for quantification of radionuclidic impurities.

Results

The content of long-lived (68)Ge breakthrough increases over the entire period of use to more than 100 ppm. The labelling process with the chelator DOTA removes (68)Ge efficiently. The maximum activity found in the residues of the radiopharmaceuticals investigated in this study was below 10 Bq in nearly all cases. In many cases (12% of the labelled substance), the long-lived parent nuclide could not be identified at all. The labelling process is still viable for reduced amounts of the chelator and with acetate buffer.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。