Remote device monitoring for implantable cardioverter defibrillators during the COVID-19 pandemic

COVID-19 疫情期间对植入式心脏复律除颤器进行远程设备监测

阅读:1

Abstract

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Remote monitoring (RM) for implantable cardioverter defibrillators (ICDs) is recommended as the standard of care in clinical guidelines. Presumably, the restrictions on face-to-face visits that were imposed during the coronavirus (COVID-19) pandemic have further accelerated the adoption of RM. However, quantitative real-world data on the uptake of RM during the COVID-19 pandemic is lacking. PURPOSE: To assess the uptake of RM during the COVID-19 pandemic to a pre-COVID-19 period, and compare the arrhythmic burden between the two groups. METHODS: This is a substudy of the retrospective, observational single-center DISTANT-study. For this substudy, data from patients who were enrolled in the RM program after de novo ICD implantation (single- and dual chamber, biventricular or subcutaneous ICDs) were analysed. The time until RM was initiated per patient was calculated for patient implanted during the COVID-19 pandemic (March 2020-January 2021) and compared to a similar 10-month period pre-COVID-19 (May 2019-March 2020). ICD therapy (shock and/or anti-tachycardia pacing), non-sustained ventricular tachycardia (NSVT), supraventricular tachycardia (SVT) and mortality were registered for each patient. Patients <18 years old at implantation and patients with a follow-up of <6 months were excluded from this analysis. RESULTS: A total of 134 patients (72.4 % male, mean age 57.3 ±14.9 years) were eligible for this substudy, of which 61 patients in the COVID-19 group and 73 patients in the pre-COVID-19 group. In both groups there was a similar percentage of primary prevention ICD implantations (COVID-19: 43%, pre-COVID: 44%; p=0.888). During COVID-19, RM was initiated more promptly following ICD implantation compared to pre-COVID-19 (respectively 63 days vs. 131 days; p=0.007). Second, in the COVID-19 group 60.7% patients were enrolled in RM within 30 days following implantation compared to 39.7% in the pre-COVID-19 group (p=0.016). In terms of arrhythmic burden, no differences in the occurrence of ICD therapy (p=0.759), NSVT (p=0.267) and SVT (p=0.454) were observed. CONCLUSION: During the COVID-19 pandemic RM was initiated more promptly following ICD implantation compared to before the pandemic, however, no differences in arrhythmic burden between groups were observed.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。