Objective Sleep Assessments in Patients with Postural Tachycardia Syndrome using Overnight Polysomnograms

利用整夜多导睡眠图对体位性心动过速综合征患者进行客观睡眠评估

阅读:1

Abstract

STUDY OBJECTIVES: Patients with postural tachycardia syndrome (POTS) commonly complain of fatigue, unrefreshing sleep, daytime sleepiness, and diminished quality of life. The study objective was to assess objective sleep quality in POTS patients using overnight polysomnography. METHODS: We studied 16 patients with POTS and 15 healthy control subjects performing daytime autonomic functions tests and overnight polysomnography at the Vanderbilt Clinical Research Center. RESULTS: There were no significant differences in the objective sleep parameters including sleep efficiency, sleep onset latency, wake time after sleep onset, REM latency, percentage of time spent in N1, N2, N3, and REM sleep, arousal index, apnea-hypopnea index, or periodic leg movement index in POTS patients as compared with healthy control subjects. There were significant negative correlations between sleep efficiency and the change in HR from supine to stand (rs = -0.527; p = 0.036). CONCLUSIONS: POTS patients do not have significant differences in objective sleep parameters as compared to control subjects based on overnight polysomnograms. Activation of the sympathetic nervous system may contribute significantly to the hyper arousal state and worsening of subjective estimates of sleep quality as previously reported in POTS patients.