The correlation between cervical range of motion and misplacement of cervical pedicle screws during cervical posterior spinal fixation surgery using a CT-based navigation system

利用基于CT导航系统的颈椎后路脊柱固定术中颈椎活动范围与颈椎椎弓根螺钉错位之间的相关性

阅读:1

Abstract

PURPOSE: The aim of this study was to analyze the correlation between cervical range of motion and cervical pedicle screw (CPS) misplacement in cervical posterior spinal fusion surgery using a CT-based navigation system. METHODS: A total of 46 consecutive patients with cervical posterior spinal fusion surgery using CPSs were evaluated retrospectively. We analyzed the cervical range of motion (ROM) and the misplacement of CPSs that were placed using either separate or single-time multilevel registration with a CT-based navigation system to determine the optimum registration procedure. The screw-inserted vertebra was indicated as Registered vertebra-Pedicle Screw inserted vertebra (Re-PS) = 0, 1, 2, or 3 depending on its distance (level) from the registered vertebra. Grades 0 (no perforation) and 1 (perforations <2 mm) were categorized as "no misplacement." Grades 2 (perforations ≧ 2 mm but < 4 mm) and 3 (perforations ≧ 4 mm) were categorized as "misplacement." We analyzed the correlations between CPS misplacement and Re-PS, and between CPS misplacement and preoperative cervical ROM. RESULTS: Our analysis included 196 screws in patients having a mean age of 53.2 years (range 5-84 years). Level of insertion relative to registration was Re-PS = 0 in 129 screws, Re-PS = 1 in 53, Re-PS = 2 in 10 and Re-PS = 3 in 4. The misplacement rates were 12.2 % (24 screws) overall, 6.2 % in Re-PS = 0, 22.6 % in Re-PS = 1, 20 % in Re-PS = 2, and 50 % in Re-PS = 3. The rate of CPS misplacement increased significantly with a Re-PS = 1 and a Re-PS = 2 and 3 compared to a Re-PS = 0. There was a significant difference in the cervical ROM in each grade and both misplacement groups: 1.8 in Grade 0, 2.3 in Grade 1, 7.8 in Grade 2, 12.9 in Grade 3, 11 in the misplacement group and 1.9 in the no misplacement group. CONCLUSIONS: The precision of CPS placement in CT-based navigation surgery was evaluated. The misplacement rate in single-time multilevel registration increased to 23.4 % compared to 6.2 % for separate registration. As the distance increased between the registered level and the level of CPS insertion, the preoperative cervical ROM and the rate of CPS misplacement significantly increased. Thus, the rate of misplacement of CPSs is reduced when performing separate registration. Furthermore, when there is greater preoperative cervical ROM, separate registration would likely improve the safety and accuracy of CPS insertion.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。