A comparative study of axis-line-distance technique and Cobb method on assessing the curative effect on scoliosis

轴线距离法与Cobb法在评估脊柱侧弯疗效方面的比较研究

阅读:1

Abstract

PURPOSE: To compare the axis-line-distance technique (ALDT) and Cobb method for therapeutic evaluation of scoliosis. METHODS: Fifty-seven patients with scoliosis were treated in our hospital, 47 underwent conservative bracing therapy and 10 underwent surgery. Based on 171 full-spine X-ray images obtained from these 57 cases before treatment, during conservative treatment or surgery, and at final follow-up after removing the brace or after surgery, two radiologists independently measured and calculated the correction rate during treatment and at final follow-up and the rate of correction loss after treatment with the ALDT and Cobb methods. Paired t-test and correlation analysis were performed. RESULTS: Based on the ALDT, the lateral deviations of the apical vertebrae before treatment, during treatment, and at final follow-up were 31 ± 14 mm, 16 ± 8 mm, and 20 ± 8 mm, respectively; the correction rates during treatment and at final follow-up were 48.7 ± 21.2% and 37.6 ± 14.2%, respectively, and the rate of correction loss after treatment was 11.3 ± 6.5%. The Cobb angles of scoliosis before treatment, during treatment, and at final follow-up were 34 ± 14°, 19 ± 7°, and 22 ± 6°, respectively; the correction rates during treatment and at final follow-up were 44.4 ± 17.3% and 33.9 ± 14.4%, respectively, and the rate of correction loss after treatment was 11.4 ± 4.3%. Calculation of the correction rate during treatment differed significantly between the two radiologists when using the Cobb method (P < 0.05); their calculations of the correction rate and rate of correction loss were not different (P > 0.05). The measurement data of the two radiologists using the Cobb method showed a weak to moderate correlation (r = 0.49, 0.57, and 0.51, respectively). When using the ALDT, there were no significant differences between the radiologists in their measurements of the correction rate during and after treatment (P > 0.05) or in the rate of correction loss. The measurement data of the two radiologists using the ALDT showed a good to excellent correlation (r = 0.92, 0.93, and 0.90, respectively). CONCLUSION: The ALDT is better than the Cobb method for therapeutic evaluation of scoliosis during treatment and at follow-up visits.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。