Three-dimensional movements of the lumbar spine facet joints and segmental movements: in vivo examinations of normal subjects with a new non-invasive method

利用一种新的非侵入性方法对正常受试者进行腰椎小关节三维运动和节段运动的体内检查

阅读:1

Abstract

INTRODUCTION: Examination with CT and image registration is a new technique that we have previously used to assess 3D segmental motions in the lumbar spine in a phantom. Current multi-slice computed tomography (CT) offers highly accurate spatial volume resolution without significant distortion and modern CT scanners makes it possible to reduce the radiation dose to the patients. Our aim was to assess segmental movement in the lumbar spine with the aforementioned method in healthy subjects and also to determine rotation accuracy on phantom vertebrae. MATERIAL AND METHOD: The subjects were examined in flexion-extension using low dose CT. Eleven healthy, asymptomatic subjects participated in the current study. The subjects were placed on a custom made jig which could provoke the lumbar spine into flexion or extension. CT examination in flexion and extension was performed. The image analysis was performed using a 3D volume fusion tool, registering one of the vertebrae, and then measuring Euler angles and distances in the registered volumes. RESULTS: The mean 3D facet joint translation at L4-L5 was in the right facet joint 6.1 mm (3.1-8.3), left facet joint 6.9 mm (4.9-9.9), at L5-S1: right facet joint 4.5 mm (1.4-6.9), and for the left facet joint 4.8 mm (2.0-7.7). In subjects the mean angles at the L4-L5 level were: in the sagittal plane 14.3°, coronal plane 0.9° (-0.6 to 2.8), and in the transverse plane 0.6° (-0.4 to 1.5), in the L5-S1 level the rotation was in sagittal plane 10.2° (2.4-16.1), coronal plane 0° (-1.2 to 1.2), and in the transverse plane 0.2° (-0.7 to 0.3). Repeated analysis for 3D facet joint movement was on average 5 mm with a standard error of mean of 0.6 mm and repeatability of 1.8 mm (CI 95%). For segmental rotation in the sagittal plane the mean rotation was 11.5° and standard error of mean 1°. The repeatability for rotation was 2.8° (CI 95%). The accuracy for rotation in the phantom was in the sagittal plane 0.7°, coronal plane 1°, and 0.7 in the transverse plane. CONCLUSION: This method to assess movement in the lumbar spine is a truly 3D method with a high precision giving both visual and numerical output. We believe that this method for measuring spine movement is useful both in research and in clinical settings.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。