Mechanical implant failure in posterior cervical spine fusion

后路颈椎融合术中机械植入物失效

阅读:1

Abstract

PURPOSE: The aim of this study was to determine whether the recent refinement and downsizing of the implants for posterior cervical fusion increase the occurrence of implant failure. METHODS: One hundred forty-two consecutive cases of cervical fusion, using either cannulated Magerl screws or a multiaxial pedicle screw-rod system, were reviewed retrospectively after an average follow-up period of more than 3 years, and the rate and characteristics of the failure of these implants were evaluated. RESULTS: Implant failure occurred in six (4.2%) patients: five with rheumatoid arthritis and one with athetoid cerebral palsy. Occipital plate fracture occurred in two patients, Magerl screw breakage in one patient, cervical pedicle screw fracture in two patients, and disassembly of the pedicle screw and rod in two patients (one with an occipital plate fracture). There was no rod fracture. The implant failures were asymptomatic, except in one patient. Disassembly of the pedicle screw and rod was observed immediately after another surgical procedure under general anesthesia in two patients. CONCLUSIONS: The failure rate of 4.2% was similar to the rates reported in the literature for posterior lumbar spinal fusion, confirming the reliability of the recent cervical screw-rod system.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。