AO-classification of thoracic and lumbar fractures--reproducibility utilizing radiographs and clinical information

胸腰椎骨折的AO分类——利用X线片和临床信息进行重复性评估

阅读:1

Abstract

This study was designed to assess the inter-observer reliability and intra-observer reproducibility of standard radiographic evaluation of 150 thoraco-lumbar fractures using the AO-classification. The influence of clinical information on agreement levels was also evaluated. Six observers (two junior and four senior residents) evaluated the radiographic images. The injuries were classified by each observer as either type A, B or C according to the AO-classification system and the levels of agreement were documented. After 3 months the injuries were again classified with the addition of the clinical findings of each patient and the level of agreement evaluated. The level of agreement was measured using Cohen's kappa-test. The overall inter-observer agreement was rated as fair (0.291) in the first session and moderate (0.403) in the second. Intra-observer values ranged from slight (0.181) to moderate (0.488). The increased level of agreement in the second session was attributed to the value of additional clinical information, the learning curve of the junior residents and the simplicity of the classification.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。