Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data

颈椎椎弓根螺钉置入术:基于形态测量数据的两种新型置入技术的可行性和准确性

阅读:1

Abstract

This morphometric and experimental study was designed to assess the dimensions and axes of the subaxial cervical pedicles and to compare the accuracy of two different techniques for subaxial cervical pedicle screw (CPS) placement using newly designed aiming devices. Transpedicular fixation is increasingly used for stabilizing the subaxial cervical spine. Development of the demanding technique is based on morphometric studies of the pedicle anatomy. Several surgical techniques have been developed and evaluated with respect to their feasibility and accuracy. The study was carried out on six conserved human cadavers (average age 85 years). Axes and dimensions of the pedicles C3-C7 (60 pedicles) were measured using multislice computed tomography (CT) images prior to surgery. Two groups consisting of 3 specimens and 30 pedicles each were established according to the screw placement technique. For surgical technique 1 (ST1) a para-articular mini-laminotomy was performed. Guidance of the drill through the pedicle with a handheld aiming device attached onto the medial aspect of the pedicle inside the spinal canal. Screw hole preparation monitored by lateral fluoroscopy. In surgical technique 2 (ST2) a more complex aiming device was used for screw holes drilling. It consists of a frame with a fully adjustable radiolucent arm for carrying the instruments necessary for placing the screws. The arm was angled according to the cervical pedicle axis as determined by the preoperative CT scans. Drilling was monitored by lateral fluoroscopy. In either technique 3.5 mm screws made of carbon fiber polyetheretherketone (CF-PEEK) were inserted. The use of the CF-PEEK screws allowed for precise postoperative CT-assessment since this material does not cause artifacts. Screw placement was qualified from ideal to unacceptable into four grades: I = screw centered in pedicle; IIa = perforation of pedicle wall less than one-fourth of the screw diameter; IIb = perforation more than one-fourth of the screw diameter without contact to neurovascular structures; III = screw more than one-fourth outside the pedicle with contact to neurovascular structures. Fifty-six pedicle screws could be evaluated according to the same CT protocol that was used preoperatively. Accuracy of pedicle screw placement did not reveal significant differences between techniques 1 and 2. A tendency towards less severe misplacements (grade III) was seen in ST2 (15% in ST2 vs. 23% in ST1) as well as a higher rate of screw positions graded IIa (62% in ST2 vs. 43% in ST1). C4 and C5 were identified to be the most critical vertebral levels with three malpositioned screws each. Because of the variability of cervical pedicles preoperative CT evaluation with multiplanar reconstructions of the pedicle anatomy is essential for transpedicular screw placement in the cervical spine. Cadaver studies remain mandatory to develop safer and technically less demanding procedures. A similar study is projected to further develop the technique of CPS fixation with regard to safety and clinical practicability.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。