Frequency of lower extremity artery disease in type 2 diabetic patients using pulse oximetry and the ankle-brachial index

利用脉搏血氧饱和度和踝臂指数评估2型糖尿病患者下肢动脉疾病的发生率

阅读:1

Abstract

Objectives: To determine the of undiagnosed lower extremity artery disease using the pulse oximetry in a type 2 diabetic population sample. Methods: Observational, cross-sectional, descriptive study that included 594 type 2 diabetic patients, with no previous history of lower extremity artery disease. Medical history, physical examination, determination of the ankle-brachial index (portable Doppler) and measurement of oxygen saturation in upper and lower extremities (pulse oximeter) were performed. Results: Frequency of lower extremity artery disease determined by ankle-brachial index was 18.4%. No significant correlations were detected between oxygen saturation and the ankle-brachial index except for the relationship between ankle-brachial index vs. oxygen saturation at 30 cm lower limb elevation vs. the supine position at no elevation (0 cm) in subjects under the age of 40. Pulse oximetry showed little diagnostic value in the screening of lower extremity artery disease. A relationship between lower extremity artery disease and age has been found. Its diagnosis was associated with a lower body mass index and lower systolic blood pressure in the lower extremities and higher in the upper extremities. Conclusions: We conclude that pulse oximetry is not useful in the screening for asymptomatic lower extremity artery disease in type 2 diabetics.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。