Electrical impedance spectroscopy of plant cells in aqueous buffer media over a wide frequency range of 4 Hz to 20 GHz

在4 Hz至20 GHz的宽频率范围内,对水性缓冲介质中的植物细胞进行电化学阻抗谱分析

阅读:1

Abstract

Electrical impedance spectroscopy was performed on suspensions of plant cells in aqueous buffer media over a wide frequency range of 4 Hz to 20 GHz. Custom probes were designed, manufactured, and used for these investigations. Experiments were performed with a custom-made parallel plate probe and impedance analysers in the low-frequency range (4 Hz to 5 MHz), with a custom-made coaxial airline probe and a vector network analyser in the mid-frequency range (100 kHz to 3 GHz), and with a commercial open-ended probe and a vector network analyser in the high-frequency range (200 MHz to 20 GHz). The impedance data acquired were processed in order to eliminate the effects of parasitics and compensate for geometrical differences between the three probes. Following this, the data were fitted to a unified model consisting of the Randles and Debye models. The data were also normalized to a reference measurement, in order to accentuate the effects of cell concentration on the impedance of the suspensions.•The methodology allows for impedance spectroscopy of cell suspensions over a wide frequency range spanning 10 orders of magnitude.•It allows for compensation of parasitics and of geometrical variations between probes, using mathematical techniques.