Structural testing of concrete walls on-edge with combined axial and out-of-plane loading

对承受轴向和面外荷载组合作用的立式混凝土墙进行结构试验

阅读:1

Abstract

Full-scale testing of structural components can be time consuming and difficult. The design of full-scale slender concrete walls is highly influenced and controlled by second-order and out-of-plane bending loads. Previous experiments on out-plane bending of slender walls and insulated walls have been performed with bending in the direction of gravity (with or against). Additionally, most of the research considering out-of-plane bending does not include an axial load and suffers from inaccurate results due to not simulating the actual loading and constraining conditions or safety issues. This testing method was developed expressly for the determination of slender wall behavior in insulated concrete panels and verified on solid slender walls, which are well understood. The testing setup presented has the following advantages•Reduces the risk of cracking panel prior to testing and provides safe and rapid testing.•Offers ease of implementation in labs with height restrictions, given sufficient floor space.•Integrates axial and lateral uniform loading.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。