Abstract
AIM: To establish equivalence in the pharmacokinetic (PK) and pharmacodynamic (PD) endpoints between proposed biosimilar Insulin-R (Biocon's Insulin-R) and Humulin® R using the euglycaemic clamp technique in healthy subjects. MATERIALS AND METHODS: In this phase-1 automated euglycaemic glucose clamp study, 42 healthy subjects were randomized (1:1) to receive a single dose of 0.3 IU/kg of Biocon's Insulin-R and Humulin-R. Plasma insulin concentrations and glucose infusion rates (GIRs) were assessed over 12 hours. Primary PK endpoints were area under the insulin concentration-time curve from 0 to 12 hours (AUC(ins.0-12h) ) and maximum insulin concentration (C(ins.max) ). Primary PD endpoints were area under the GIR time curve from 0 to 12 hours (AUC(GIR.0-12h) ) and maximum GIR (GIR(max) ). RESULTS: Equivalence was demonstrated between Biocon's Insulin-R and Humulin-R for the primary PK and PD endpoints. The 90% confidence intervals were within 80.00% to 125.00% limits. The PK and PD profiles were comparable. There were no significant differences in the safety profiles of the two treatments, and no serious adverse events were reported. CONCLUSION: PK and PD equivalence was demonstrated between Biocon's Insulin-R and Humulin-R in healthy subjects. Treatment with Biocon's Insulin-R and Humulin-R was well tolerated.