Detection of QT prolongation using a novel electrocardiographic analysis algorithm applying intelligent automation: prospective blinded evaluation using the Cardiac Safety Research Consortium electrocardiographic database

利用智能自动化技术,通过新型心电图分析算法检测QT间期延长:基于心脏安全研究联盟心电图数据库的前瞻性盲法评估

阅读:1

Abstract

BACKGROUND: The Cardiac Safety Research Consortium (CSRC) provides both "learning" and blinded "testing" digital electrocardiographic (ECG) data sets from thorough QT (TQT) studies annotated for submission to the US Food and Drug Administration (FDA) to developers of ECG analysis technologies. This article reports the first results from a blinded testing data set that examines developer reanalysis of original sponsor-reported core laboratory data. METHODS: A total of 11,925 anonymized ECGs including both moxifloxacin and placebo arms of a parallel-group TQT in 181 subjects were blindly analyzed using a novel ECG analysis algorithm applying intelligent automation. Developer-measured ECG intervals were submitted to CSRC for unblinding, temporal reconstruction of the TQT exposures, and statistical comparison to core laboratory findings previously submitted to FDA by the pharmaceutical sponsor. Primary comparisons included baseline-adjusted interval measurements, baseline- and placebo-adjusted moxifloxacin QTcF changes (ddQTcF), and associated variability measures. RESULTS: Developer and sponsor-reported baseline-adjusted data were similar with average differences <1 ms for all intervals. Both developer- and sponsor-reported data demonstrated assay sensitivity with similar ddQTcF changes. Average within-subject SD for triplicate QTcF measurements was significantly lower for developer- than sponsor-reported data (5.4 and 7.2 ms, respectively; P < .001). CONCLUSION: The virtually automated ECG algorithm used for this analysis produced similar yet less variable TQT results compared with the sponsor-reported study, without the use of a manual core laboratory. These findings indicate that CSRC ECG data sets can be useful for evaluating novel methods and algorithms for determining drug-induced QT/QTc prolongation. Although the results should not constitute endorsement of specific algorithms by either CSRC or FDA, the value of a public domain digital ECG warehouse to provide prospective, blinded comparisons of ECG technologies applied for QT/QTc measurement is illustrated.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。