Novel active fixation lead guided by electrical delay can improve response to cardiac resynchronization therapy in heart failure

一种新型的、由电延迟引导的主动固定导线可以改善心力衰竭患者对心脏再同步治疗的反应。

阅读:1

Abstract

AIMS: Cardiac resynchronization therapy (CRT) for heart failure (HF) recently has shown optimal results by targeting electrically delayed sites in coronary sinus (CS) branches. However this purpose often cannot be reached because of unstable left ventricular (LV) lead position. In current study were assessed the long-term effects of the novel active fixation LV lead in CS, guided by electrical delay (QLV), in patients with HF due to coronary artery disease. METHODS: One hundred eighty-five consecutive patients underwent CRT with intraoperative evaluation of QLV in the target position of the LV lead. When the novel active fixation LV lead was available, 98 consecutive patients received it, composing the Fix group. They were compared with 87 patients with a conventional passive fixation lead (No Fix group). The final LV lead position was assessed by fluoroscopy. Clinical response to CRT was assessed within a period of about 3 years: patients experiencing HF rehospitalization and death due to HF were defined as non-responders. RESULTS: There were no significant differences between groups in the final position of LV lead in left anterior oblique view (Pearson χ(2)  = 0.12; P = 0.73). In right anterior oblique view, a basal position was reached more in the Fix group (38%) than in the No Fix group (6.5%) (Pearson χ(2)  = 23.095; P < 0.001). QLV was significantly greater in the Fix group (122.6 ± 33.2 ms; SE = 3.6) than in the No Fix group (97.5 ± 37.8 ms; SE = 4.9) (t = 4.17; P < 0.001). Rehospitalizations for HF were 37 in the No Fix group and 14 in the Fix group. Deaths due to HF were 49 in the No Fix group and 18 in the Fix group. Survival analysis, assessed by Cox regression, showed that the Fix group had a better outcome both for HF rehospitalizations [hazard ratio (HR) = 0.48; 95% confidence interval (CI) = 0.25-0.9; P = 0.023] and death due to HF (HR = 0.55; 95% CI = 0.31-0.97; P = 0.04) in comparison with the No Fix group. Adjustment for baseline characteristics by multivariate analysis showed that an active fixation lead in CS, as a covariate, was still significant both for HF rehospitalizations (HR 0.46; 95% CI = 0.24-0.88; P = 0.019) and for death due to HF (HR 0.5; 95% CI = 0.28-0.9; P = 0.021). CONCLUSIONS: The novel active fixation LV lead allowed to target sites with greater QLV. Often maximum QLV was documented in basal segments, were stability of conventional passive fixation leads is not enough. Patients receiving it experienced less HF rehospitalizations and less death due to HF. Active fixation lead in CS guided by QLV can improve long-term prognosis in patients with HF due to coronary artery disease undergoing to CRT.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。