Five years comparation of efficacy and safety after ICL-V4c implantation for high and super high myopia correction

ICL-V4c植入术治疗高度和超高度近视五年疗效和安全性比较

阅读:1

Abstract

OBJECTIVES: The objective of the investigation is to examine the long term efficacy, safety, and predictability of ICL-V4c implantation for high and super-high myopic patients in order to provide reliable guidance for the selection of refractive surgical procedures. METHODS: We reviewed 125 eyes from 64 patients who implanted ICL-V4c at the Refractive Surgery Center of West China Hospital in Chengdu, China, between May 2015 and January 2017. These eyes were divided into two groups based on their preoperative spherical equivalent (SE) degree: high myopia (≥ -10D) and super-high myopia groups (< -10D). We followed up with the patients over 5 years and evaluated several parameters, including uncorrected visual acuity (UDVA), corrected visual acuity (CDVA), axial length (AL), refractive error, endothelial cell density (ECD), intraocular pressure (IOP), white-to-white distance (WTW), and vault. RESULTS: The efficacy indices of ICL-V4c implantation in high and super-high myopia groups were 0.91 ± 0.23 and 0.80 ± 0.25, respectively at 5 years after operation. Compared to high myopia group, the efficacy index of super-high myopia was obviously decreased (p = 0.020) and the △AL of super-high myopia was significantly increased (p = 0.001). The mean safety indices were 1.10 ± 0.15 and 1.10 ± 0.21 respectively in high and super-high myopia groups (p = 0.850). At the 5-year mark, 11.67% vs 20.00% (High vs Super-high) of eyes were within ±0.50 D (Spherical Equivalent), and 75.00% vs 70.77% (High vs Super-high) of eyes were within ±2.00 D. No significant difference of ECD was found in the high (2823.45 ± 274.75 cells/mm(2)) and super-high myopia (2856.71 ± 323.53cells/mm(2)) at the visit of 5 years. Compared to baseline, we observed a significant increase in IOP at the 1-week follow-up, which decreased significantly at the one-month visit. Furthermore, there was a significant difference of vault between the high and super-high groups at 1-month (p = 0.042) and 5-year (p = 0.002) after surgery. CONCLUSIONS: ICL-V4c implantation is effective, safe, and stable for correcting high and super-high myopia. However, ophthalmologists need to be aware of the potential for greater myopia regression in super-high myopic patients, as well as the increase in axial length and associated fundus complications.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。