Smartwatch-Based Maximum Oxygen Consumption Measurement for Predicting Acute Mountain Sickness: Diagnostic Accuracy Evaluation Study

基于智能手表的最大摄氧量测量预测急性高原反应:诊断准确性评估研究

阅读:1

Abstract

BACKGROUND: Cardiorespiratory fitness plays an important role in coping with hypoxic stress at high altitudes. However, the association of cardiorespiratory fitness with the development of acute mountain sickness (AMS) has not yet been evaluated. Wearable technology devices provide a feasible assessment of cardiorespiratory fitness, which is quantifiable as maximum oxygen consumption (VO(2)max) and may contribute to AMS prediction. OBJECTIVE: We aimed to determine the validity of VO(2)max estimated by the smartwatch test (SWT), which can be self-administered, in order to overcome the limitations of clinical VO(2)max measurements. We also aimed to evaluate the performance of a VO(2)max-SWT-based model in predicting susceptibility to AMS. METHODS: Both SWT and cardiopulmonary exercise test (CPET) were performed for VO(2)max measurements in 46 healthy participants at low altitude (300 m) and in 41 of them at high altitude (3900 m). The characteristics of the red blood cells and hemoglobin levels in all the participants were analyzed by routine blood examination before the exercise tests. The Bland-Altman method was used for bias and precision assessment. Multivariate logistic regression was performed to analyze the correlation between AMS and the candidate variables. A receiver operating characteristic curve was used to evaluate the efficacy of VO(2)max in predicting AMS. RESULTS: VO(2)max decreased after acute high altitude exposure, as measured by CPET (25.20 [SD 6.46] vs 30.17 [SD 5.01] at low altitude; P<.001) and SWT (26.17 [SD 6.71] vs 31.28 [SD 5.17] at low altitude; P<.001). Both at low and high altitudes, VO(2)max was slightly overestimated by SWT but had considerable accuracy as the mean absolute percentage error (<7%) and mean absolute error (<2 mL·kg(-1)·min(-1)), with a relatively small bias compared with VO(2)max-CPET. Twenty of the 46 participants developed AMS at 3900 m, and their VO(2)max was significantly lower than that of those without AMS (CPET: 27.80 [SD 4.55] vs 32.00 [SD 4.64], respectively; P=.004; SWT: 28.00 [IQR 25.25-32.00] vs 32.00 [IQR 30.00-37.00], respectively; P=.001). VO(2)max-CPET, VO(2)max-SWT, and red blood cell distribution width-coefficient of variation (RDW-CV) were found to be independent predictors of AMS. To increase the prediction accuracy, we used combination models. The combination of VO(2)max-SWT and RDW-CV showed the largest area under the curve for all parameters and models, which increased the area under the curve from 0.785 for VO(2)max-SWT alone to 0.839. CONCLUSIONS: Our study demonstrates that the smartwatch device can be a feasible approach for estimating VO(2)max. In both low and high altitudes, VO(2)max-SWT showed a systematic bias toward a calibration point, slightly overestimating the proper VO(2)max when investigated in healthy participants. The SWT-based VO(2)max at low altitude is an effective indicator of AMS and helps to better identify susceptible individuals following acute high-altitude exposure, particularly by combining the RDW-CV at low altitude. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR2200059900; https://www.chictr.org.cn/showproj.html?proj=170253.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。