Hemostatic function and transfusion efficacy of apheresis platelet concentrates treated with gamma irradiation in use for thrombocytopenic patients

用于血小板减少症患者的经γ射线照射处理的单采血小板浓缩液的止血功能和输血疗效

阅读:1

Abstract

BACKGROUND: During the transfusion of blood components, the transfer of allogeneic donor white blood cells (WBCs) can mediate transfusion-associated graft-versus-host disease (TA-GVHD). To minimize the reaction, exposure of blood products to gamma irradiation is currently the standard of care. The aim of our study was to evaluate and compare hemostatic function, transfusion efficacy, and safety of gamma-irradiated single-donor apheresis platelet concentrates (PCs) and of conventional non-irradiated PCs in patients with chemotherapy-induced thrombocytopenia. METHODS: 20 double-dose single-donor leukoreduced PCs were split in two identical units; one was gamma-irradiated with 25 Gy (study arm A) and the other remains non-irradiated (study arm B). Both units were stored under equal conditions. Hematologic patients were randomly assigned to receive gamma-irradiated or conventional non-irradiated PCs. Hemostatic function was evaluated by thrombelastography (TEG). TEG measurements were taken pre transfusion and 1 and 24 h post transfusion. TEG profiles were measured, noting the time to initiate clotting (R), the angle of clot formation (α), and the maximum amplitude (clot strength (MA)). Whole blood samples were collected from these thrombocytopenic patients at 1 and 24 h for PLT count increments (CIs) and corrected count increments (CCIs) with assessments of transfusion efficacy. Time to next PLT transfusion, transfusion requirement of RBCs, active bleeding, and adverse events (AEs), were analyzed. RESULTS: No differences could be found in hemostatic function parameters (MA, R, and α) between study arms A and B (all p values > 0.096) pre transfusion as well as 1 and 24 h post transfusion. No differences between study arms A and B were observed for mean (± standard deviation (SD)) 1-hour CCI (12.83 ± 6.33 vs. 11.59 ± 5.97) and 24-hour CCI (6.56 ± 4.10 vs. 5.76 ± 4.05). Mean 1-hour CI and 24-hour CI were not significantly different in both study arms (p = 0.254 and p = 0.242 respectively). Median time to the next PC transfusion after study PC was not significantly different between groups: (2.4 vs. 2.2 days, p = 0.767). No differences could be found in transfusion requirement of red blood cells (p = 0.744) between both study arms. There were also no regarding bleeding, adverse events, and acute transfusion reaction(s). CONCLUSIONS: This study confirms safety of gamma-irradiated PCs for treatment thrombocytopenia. Hemostatic function, transfusion efficacy, bleeding, and safety of single-donor apheresis PCs treated with gamma irradiation versus untreated control PCs are comparable.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。