Conclusions
The frequency of pathogen isolates in invasive medical devices exhibited an association with SARS-CoV-2 infection. Critically ill patients with SARS-CoV-2 are more prone to developing early-onset VAP than those without SARS-CoV-2 infection.
Results
Our study included 127 patients without SARS-CoV-2 infection and 140 patients with SARS-CoV-2 infection. The findings indicated a higher incidence of HAI caused by various microorganisms associated with any medical device in patients with SARS-CoV-2 (HR = 6.86; 95% CI-95%: 3.26-14.43; p < 0.01). After adjusting for ICU duration and ventilator days, a heightened frequency of HAIs persisted in SARS-CoV-2-infected individuals. However, a detailed examination of HAIs revealed that only ventilation-associated pneumonia (VAP) displayed a significant association (HR = 6.69; 95% CI: 2.59-17.31; p < 0.01). A statistically significant correlation between SARS-CoV-2 infection and the isolation of S. aureus was also observed (p = 0.034). The prevalence of S. aureus infection was notably higher in patients with SARS-CoV-2 (RR = 8.080; 95% CI: 1.052-62.068; p < 0.01). Conclusions: The frequency of pathogen isolates in invasive medical devices exhibited an association with SARS-CoV-2 infection. Critically ill patients with SARS-CoV-2 are more prone to developing early-onset VAP than those without SARS-CoV-2 infection.