Revision of 33 unicompartmental knee prostheses using total knee arthroplasty: strategy and results

采用全膝关节置换术翻修33例单髁膝关节假体:策略和结果

阅读:1

Abstract

The purpose of this study was twofold: to evaluate the radiological and clinical results of 33 total knee arthroplasties (TKA) implanted between January 1993 and March 2005, to replace failed medial unicompartmental knee arthroplasty (UKA), and to develop a strategy to deal with bone defects in the tibial plateau. Failure was due to: tibial loosening (15 cases), femoral loosening (five cases), femoral and tibial loosening (two cases), polyethylene wear (five cases), lateral compartment osteoarthritis (two cases), patellofemoral osteoarthritis (two cases), laxity and PE dislocation (one case), and sepsis in one case. In 12 cases the tibial bone defect was filled with a metallic wedge, in seven we used an allograft (femoral head), and in one we used both. We report the results of 27 cases (five patients died and one was lost to follow-up). The mean follow-up was 73+/-41.7 months (range, 8-153) and the global IKS score was 166.72+/-21.3 points (range, 128-200). X-rays of the eight allografts showed osteointegration in all cases and no radiolucency was noted.