Association of Intravenous Radiocontrast With Kidney Function: A Regression Discontinuity Analysis

静脉注射放射造影剂与肾功能的关系:回归不连续性分析

阅读:1

Abstract

IMPORTANCE: Radiocontrast has long been thought of as nephrotoxic; however, a number of recent observational studies found no evidence of an association between intravenous contrast and kidney injury. Because these studies are at high risk of confounding and selection bias, alternative study designs are required to enable more robust evaluation of this association. OBJECTIVE: To determine whether intravenous radiocontrast exposure is associated with clinically significant long-term kidney impairment, using a study design that permits stronger causal interpretation than existing observational research. DESIGN, SETTING, AND PARTICIPANTS: This cohort study included all emergency department patients aged 18 years or older undergoing D-dimer testing between 2013 and 2018 in the Canadian province of Alberta. A fuzzy regression discontinuity design was used, exploiting the fact that individuals just either side of the eligibility cutoff for computed tomographic pulmonary angiogram (CTPA)-typically 500 ng/mL-have markedly different probabilities of contrast exposure, but should otherwise be similar with respect to potential confounders. EXPOSURES: Intravenous contrast in the form of a CTPA. MAIN OUTCOMES AND MEASURES: Estimated glomerular filtration rate (eGFR) up to 6 months following the index emergency department visit. RESULTS: During the study period 156 028 individuals received a D-dimer test. The mean age was 53 years, 68 206 (44%) were men and 87 822 (56%) were women, and the mean baseline eGFR level was 86 mL/min/1.73 m2. Patients just above and below the CTPA eligibility cutoff were similar in terms of measured confounders. There was no evidence for an association of contrast with eGFR up to 6 months later, with a mean change in eGFR of -0.4 mL/min/1.73 m2 (95% CI, -4.9 to 4.0) associated with CTPA exposure. There was similarly no evidence for an association with need for kidney replacement therapy (risk difference [RD], 0.07%; 95% CI, -0.47% to 0.61%), mortality (RD, 0.3%; 95% CI, -2.9% to 3.2%), and acute kidney injury (RD, 4.3%; 95% CI, -2.7% to 12.9%), though the latter analysis was limited by missing data. Subgroup analyses were potentially consistent with harm among patients with diabetes (mean eGFR change -6.4 mL/min/1.73 m2; 95% CI, -15.4 to 0.2), but not among those with other reported risk factors for contrast-induced nephropathy; these analyses, however, were relatively underpowered. CONCLUSIONS AND RELEVANCE: Using a cohort study design and analysis that permits stronger causal interpretation than existing observational research, we found no evidence for a harmful effect on kidney function of intravenous contrast administered for CTPA in an emergency setting.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。