Effect of Portable Air Filtration Systems on Personal Exposure to Fine Particulate Matter and Blood Pressure Among Residents in a Low-Income Senior Facility: A Randomized Clinical Trial

便携式空气过滤系统对低收入老年机构居民细颗粒物暴露和血压的影响:一项随机临床试验

阅读:1

Abstract

IMPORTANCE: Fine particulate matter (smaller than 2.5 μm) (PM2.5) air pollution is a major global risk factor for cardiovascular (CV) morbidity and mortality. Few studies have tested the benefits of portable air filtration systems in urban settings in the United States. OBJECTIVE: To investigate the effectiveness of air filtration at reducing personal exposures to PM2.5 and mitigating related CV health effects among older adults in a typical US urban location. DESIGN, SETTING, AND PARTICIPANTS: This randomized, double-blind crossover intervention study was conducted from October 21, 2014, through November 4, 2016, in a low-income senior residential building in Detroit, Michigan. Forty nonsmoking older adults were enrolled, with daily CV health outcome and PM2.5 exposure measurements. INTERVENTIONS: Participants were exposed to the following three 3-day scenarios separated by 1-week washout periods: unfiltered air (sham filtration), low-efficiency (LE) high-efficiency particulate arrestance (HEPA)-type filtered air, and high-efficiency (HE) true-HEPA filtered air using filtration systems in their bedroom and living room. MAIN OUTCOMES AND MEASURES: The primary outcome was brachial blood pressure (BP). Secondary outcomes included aortic hemodynamics, pulse-wave velocity, and heart rate variability. Exposures to PM2.5 were measured in the participants' residences and by personal monitoring. RESULTS: The 40 participants had a mean (SD) age of 67 (8) years (62% men). Personal PM2.5 exposures were significantly reduced by air filtration from a mean (SD) of 15.5 (10.9) μg/m3 with sham filtration to 10.9 (7.4) μg/m3 with LE fitration and 7.4 (3.3) μg/m3 with HE filtration. Compared with sham filtration, any filtration for 3 days decreased brachial systolic and diastolic BP by 3.2 mm Hg (95% CI, -6.1 to -0.2 mm Hg) and 1.5 mm Hg (95% CI, -3.3 to 0.2 mm Hg), respectively. A continuous decrease occurred in systolic and diastolic BP during the 3-day period of LE filtration, with a mean of 3.4 mm Hg (95% CI, -6.8 to -0.1 mm Hg) and 2.2 mm Hg (95% CI, -4.2 to -0.3 mm Hg), respectively. For HE filtration, systolic and diastolic BP decreased by 2.9 mm Hg (95% CI, -6.2 to 0.5 mm Hg) and 0.8 mm Hg (95% CI, -2.8 to 1.2 mm Hg), respectively. Most secondary outcomes were not significantly improved. CONCLUSIONS AND RELEVANCE: Results of this study showed that short-term use of portable air filtration systems reduced personal PM2.5 exposures and systolic BP among older adults living in a typical US urban location. The use of these relatively inexpensive systems is potentially cardioprotective against PM2.5 exposures and warrants further research. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03334565.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。