Developing an early warning system for detecting sepsis in patients with trauma

开发用于检测创伤患者脓毒症的早期预警系统

阅读:1

Abstract

The purpose of this study was to analyse the risk factors for sepsis in patients with trauma and develop a new scoring system for predicting sepsis in patients with trauma based on these risk factors. This will provide a simple and effective early warning method for the rapid and accurate detection and evaluation of the probability of sepsis in patients with trauma to assist in planning timely clinical interventions. We undertook a retrospective analysis of the clinical data of 216 patients with trauma who were admitted to the emergency intensive care unit of the emergency medicine department of the Hebei Medical University Third Hospital, China, between November 2017 and October 2022. We conducted a preliminary screening of the relevant factors using univariate logistic regression analysis and included those factors with a p value of <0.075 in the multivariate logistic regression analysis, from which the risk factors were screened and assigned, and obtained a total score, which was the sepsis early warning score. The incidence of sepsis in patients in the intensive care unit with trauma was 36.9%, and the mortality rate due to sepsis was 19.4%. We found statistically significant differences in several factors for patients with sepsis. The risk factors for sepsis in patients with trauma were the activated partial thromboplastin time, the New Injury Severity Score, growth differentiation factor-15 levels, shock, mechanical ventilation and the Acute Physiology and Chronic Health Evaluation II score. The area under the receiver operating characteristic curve of the sepsis early warning score for predicting sepsis in patients with trauma was 0.725. When the cutoff value of the early warning score was set at 5.0 points, the sensitivity was 69.9% and the specificity was 60.3%. The incidence of sepsis in patients with trauma can be reduced by closely monitoring patients' hemodynamics, implementing adequate fluid resuscitation promptly and by early removal of the catheter to minimize the duration of unnecessary invasive mechanical ventilation. In this study, we found that the use of the sepsis early warning score helped in a more accurate and effective evaluation of the prognosis of patients with trauma.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。