Functional, Spiroergometric, and Subjective Comparisons Between Forearm Crutches and Hands-Free Single Crutches in a Crossover Study

一项交叉研究对前臂拐杖和免手持单拐杖的功能、肺功能和主观感受进行了比较

阅读:1

Abstract

BACKGROUND: Following below-knee surgery, the optimal medical mobility device remains controversial as adequate nonweightbearing of the operated extremity is critical to ensure successful healing. The use of forearm crutches (FACs) is well established but requires using both upper extremities. The hands-free single orthosis (HFSO) is an alternative that spares the upper extremities. This pilot study compared functional, spiroergometric, and subjective parameters between HFSO and FAC. METHODS: Ten healthy (5 females, 5 males) participants were asked to use HFSOs and FACs in a randomized order. Five functional tests were performed: climbing stairs (CS), an L-shaped indoor course (IC), an outdoor course (OC), a 10-meter walk test (10MWT), and a 6-minute walk test (6MWT). Tripping events were counted while performing IC, OC, and 6MWT. Spiroergometric measurements consisted of a 2-step treadmill test with speeds of 1.5 and 2 km/h, each for 3 minutes. Lastly, a VAS questionnaire was completed to collect data regarding comfort, safety, pain, and recommendations. RESULTS: Significant differences between both aids were observed in CS and IC (HFSO: 29.3 seconds; FAC: 26.1 seconds, P < .03; and HFSO: 33.2 seconds, FAC: 18 seconds, P < .001, respectively). The other functional tests showed no significant differences. The trip events were not significantly different between the use of the 2 aids. Spiroergometric tests showed significant differences regarding heart rate (HFSO: 131.1 bpm at 1.5 km/h and 131 bpm at 2 km/h; FAC: 148.1 bpm at 1.5 km/h and 161.8 bpm at 2 km/h) and oxygen consumption (HFSO: 15.4 mL/min/kg at 1.5 km/h and 16 mL/min/kg at 2 km/h; FAC: 18.3 mL/min/kg at 1.5 km/h and 21.9 mL/min/kg at 2 km/h) at both speeds (all P < .01). In addition, significantly different ratings regarding the items comfort, pain, and recommendation were recorded. Both aids were equally rated for safety. CONCLUSION: HFSOs may be an alternative to FACs, especially in activities that require physical stamina. Further prospective studies in patients with below-knee surgical intervention concerning everyday clinical use would be interesting. LEVEL OF EVIDENCE: Level IV pilot-study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。