Spleen Dose-Volume Parameters as a Predictor of Treatment-related Lymphopenia During Definitive Chemoradiotherapy for Esophageal Cancer

脾脏剂量体积参数作为食管癌根治性放化疗期间治疗相关性淋巴细胞减少症的预测指标

阅读:1

Abstract

AIM: Our study sought to identify dosimetric predictors of treatment-related lymphopenia during chemoradiotherapy for esophageal cancer. MATERIALS AND METHODS: Patients with esophageal cancer who had received definitive chemoradiotherapy at our Institution were retrospectively assessed. The absolute volume of the spleen, body, and bone marrow that had received 5, 10, 20, and 30 Gy and the mean splenic dose were recorded. RESULTS: Multivariate linear regression analysis revealed that docetaxel use and spleen dose-volume parameters (V5, V10, V20, V30, and mean splenic dose) were significant independent factors negatively influencing the absolute lymphocyte count at nadir. An increase of 1 Gy in mean splenic dose predicted a 2.9% decrease in nadir absolute lymphocyte count. Univariable logistic regression analysis showed that the mean splenic dose was a significant predictor of grade 4 lymphopenia. None of the body or bone marrow dose-volume parameters significantly predicted lymphopenia. CONCLUSION: Higher spleen dose-volume parameters were associated with severe lymphopenia during chemoradiotherapy.