The Association Between Switching from Synthroid(®) and Clinical Outcomes: US Evidence from a Retrospective Database Analysis

从优甲乐®转换至其他药物与临床结局之间的关联:来自美国回顾性数据库分析的证据

阅读:2

Abstract

INTRODUCTION: Clinical guidelines recommend levothyroxine as the standard of care for hypothyroidism and that patients should be treated with a consistent preparation of synthetic levothyroxine without switching among formulations. This study examines the likelihoods of negative clinical outcomes between continuous users of Synthroid(®) (AbbVie, Inc.) and patients who switch from Synthroid(®) to an alternative formulation of levothyroxine. METHODS: This retrospective cohort analysis utilized data from Optum Clinformatics™ DataMart covering May 1, 2000 to March 30, 2016. After 6 months of consistent use of Synthroid(®), patients were categorized as continuous users or as switchers (by filling a prescription for an alternative formulation). Key outcomes included the likelihood of a thyroid-stimulating hormone (TSH) laboratory value out of a guideline recommended range and/or an adverse clinical composite endpoint identified by ICD codes in the patient's claims data over the following 2 years for any of the following: chronic kidney disease, depression, fatigue, heart failure, hyperlipidemia, hypertension, or obesity. Individual components of the composite endpoint were also examined. Outcomes were analyzed using multivariable logistic models on propensity score matched cohorts. Analyses controlled for patient characteristics using SAS 9.4 software. Chi-square and t tests were employed and P < 0.05 was pre-specified as statistically significant. RESULTS: Propensity score matching resulted in a sample of 9925 continuous users and 9925 switchers. Switchers were significantly more likely than continuers to have a TSH laboratory value out-of-range in the post-period [odds ratio (OR) 1.15; 95% confidence interval (CI) (1.08-1.23)]. Switchers were also more likely to have the composite clinical endpoint [OR 1.23; CI (1.12-1.37)] and to have individual diagnoses of chronic kidney disease, depression, fatigue, hypertension, or obesity in the post-period. CONCLUSIONS: Results of this large retrospective study over an extended time horizon support clinical guideline recommendations that switching among alternative formulations of synthetic levothyroxine should generally be avoided. Continuous use of Synthroid(®) was associated with a significantly higher likelihood of maintaining the TSH laboratory value within a guideline recommended range and a significantly lower likelihood of being diagnosed with adverse clinical outcomes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。